ACR10R-DxxTEx Bidirectional 3 phase Reflux Monitoring Energy Meter

          

Function

                                     

               

Function/Model

ACR10RH-DxxT(R)E4 ACR10RH-DxxT(R)E3

Display mode

LCD(Field LCD)

Measuring parameter

Current/voltage/frequency/power facto

Active power/reactive power/apparent power

Four quadrant electric energy measurement

Maximum demand

Multiple rate electric energy measurement

Power quality monitoring

Total harmonic content

subharmonic(2-31 times)

Data logging

Incident record

Display mode

Alarm

Built-in clock

Communication

RS485 interface

Optional function (choose one)

J(2DO)

A1+(B1 or C1)

(4DI+2DO or 4DI+EP)*

K(4DI)

pulse(2channels)

    

Note:

1、“■”is standard allocation function,“□”is matching function,Above instrument stanfard 1 channel RS485 communication;

2、Terminal connection mode corresponding to A1/B1/C1 and so on in selection function;

3、Pulse output and relay output can not be selected at the same time;

4、When you select an event loggong feature,you must configure the DI or DO

           

         

              

Main Parameters

          

  

Technical parameters

Indicators

Input

Net work

3-phase 3-wire,3-phase 4 wire

Frequency

45~65Hz

Voltage

Rating:AC 57.7V/100V(100V)、220V/380V(400V)

Overload:1.2-fold rating(continuous);2-fold rating/1second

Consumption:<0.2VA

Current

Rating: 80A,120A,200A .etc(See specific product specifications,special parameters can be customized)

Overload:1.2-fold rating(continuous);10-fold rating/1 second

Consumption:< 0.2VA

Output

Electric energy

Output mode:Open-collector photocoupler pulse,two way output

Three-phase

Pulse constant:4000、8000imp/kWh

Communication

RS485 interface,Modbus-RTU Protocol

Display mode

LCD

Function

Switching

Input

Four way dry contact input

Output

Output mode: two way relay nO contact output

Contact capacity:AC 250V/3A、DC 30V/3A

Measuring accuracy

Frequency0.05Hz、reactive electric energy1class、other 0.5class

Power supply

AC85~265V or DC100~350V;DC24V(±10%);DC48V(±10%)

Consumption≤10VA

Safety

Power-frequency withstand voltage

Power frequency withstand voltage between Auxiliary power and switch volume output and current input and voltage input and communication and pulse output and switch volume input terminal is AC2kV 1min;Power frequency withstand voltage between auxiliary power and switch volume output and current input voltage input terminal is AC 2kV/1min;Power frequency withstand voltage between communication and pulse output and switch volume input terminal is AC 1kV/1min;

Insulation resistance

Input,Output terminal to housing>100MΩ

Environment

Working temperature:-10℃~+55℃;Storage temperature:-20℃~+70℃

Relative humidity:5%~95% No condensation;Altitude:≤2500m

 

      

                                

Share This Items :

Product Details

     

The din-rail harmonic meter with external split core cts is suitable for energy saving renovation projects in high energy consumption industries such as smelting,steel,electric welding,semiconductor,etc.

   
          
Download

 

                 

Characteristics

                                                                                  

● Measurement: 3-phase Active Power, Reactive Power, Current, Voltage and etc

● Current Rating: up to 300A (with CTs); up to 20000A (with Rogowski Coil)
● Communication: RS485 (MODBUS-RTU)
● Application: Using in distributed Solar PV and Anti-reflux Inverter
● Display: LCD Display
● Dimension: 54*64*84mm (L*W*H)
● Installation: 35mm DIN Rail
● Power Supply: 85~265V AC or 100~350V DC
● Standard&Certificate: CE

                                                        

Product Display

                     

                                                                       

          

Used for distributed Solar PV

● Reflux Monitoring

● Connected with Load Line through CTs

● Directly connect with inverters

Application scenario of ACR10R-DxxTEx Three-phase PV Reflux Monitoring Meter

 

Bidirectional Power Metering

● Active Power Metering

● Reactive Power Metering

 

Bidirectional power metering of ACR10R-DxxTEx Three-phase PV Reflux Monitoring Meter

 

RS485 Communication

● MODBUS-RTU Protocol

● Communicate with Inverter to realize anti-reflux Function

RS485 of ACR10R-DxxTEx Three-phase PV Reflux Monitoring Meter to be communicate with inverter for Anti-reflux function

 

Paired with external CTs or Rogowski Coil

● Rated Current of CTs: up to 300A

● Rated Current of Rogowski Coil: up to 20000A

ACR10R-DxxTEx Three-phase PV Reflux Monitoring Meter paired with external CTs or Rogowski Coil

 

 

LCD Display

● Parameter Display

● Programming Interface

LCD display of ACR10R-DxxTEx Three-phase PV Reflux Monitoring Meter

 

Keypads HMI for Programming

● Parameter Display Setting

● Communication(address, baud rate and etc.)

● Wiring: 3P3W,3P4W

Keypads HMI of ACR10R-DxxTEx Three-phase PV Reflux Monitoring Meter

       

           

          

Dimension (Unit:mm) 


         

    

      

          

Practical Application 

    

    

 Solor PV Power Distribution Monitoring Solution 

Application of ACR10R-DxxT Single-phase PV Reflux Monitoring Meter in Solar PV power monitoring system

     

               

 ACR10R-DxxTEx Practical Utility In Distributed Solar PV 

Practical application of ACR10R-DxxT Single-phase PV Reflux Monitoring Meter in distributed Solar PV system

 

   

                

Latest news

Acrel Energy Meter Application In Korea Charging Pile Manufacturer

Acrel DC Energy Meter Application in Base Station in Indonesia

Application of Wireless Temperature Measurement System in Coal Mine High Voltage Electrical Equipment

Acrel Power Monitoring System Application in Pepsi Asia R&D Center

IoT Remote Power Monitoring Solution

Excellent Quality

The Impact of Grid-connected Photovoltaic Power Generation on Power Quality and Solutions

Precision distribution,multi circuits monitoring,railway transportation,leakage current

Application of Intelligent Lighting Control System in Railway Station Building

Precision distribution monitoring solution for IDC

Acrel Energy Meter Application in Base Station in Indonesia

Solar PV Energy Solution

Acrel Wireless Temperature Sensor Application in South Africa

Application and product selection of electric power monitoring system in intelligent building

Application of Active Filters in Biopharmaceutical Industry

Hydroelectric Power Plant Measurement Device Configuration Selection And Plant Power Management System

Acrel Hospital Isolated Power Supply Application in Malaysia

Energy Consumption Management System Solution

Welcome to Middle East Energy 2024

Good News! Congratulations to Acrel ADL3000-E Energy Meter for Obtaining The 1st Certificate of UL61010-2-030 Standard in China!

Centralized Monitoring System Solution for Wind Farms

Substation Operation and Maintenance Cloud Platform Solution

Advanced Technology

Professional Service

Acrel at the 48th MIDDLE EAST ENERGY DUBAI 2023

Wireless Temperature Monitoring System Solution

Application of Hall Current Sensor in Battery Cabinet Monitoring

Application Analysis of Acrel Prepaid Energy Meter and Energy Management System

Acrel Wireless Temperature Measuring Product Application in Netherlands Substation

A brief discussion on the application and development of wireless network meters in the ubiquitous power Internet of Things

Analysis and application of unattended substation operation and maintenance cloud platform

R & D Strength

Welcome to HANNOVER MESSE 2024

Warmly Welcome Malaysian Customers to Acrel for Technical Exchanges

Welcome to ENLIP EUROPE

AM5-DB Low-voltage Automatic Switching Device for Backup Power Supply Application in Dongting Substation Project of Hebei Guanyi Rongxin Technology Company

Charging Pile Energy Management System Solution

en_USEnglish