APM 8xx Series Three Phase Multifunction Power & Energy Meter

Function

Function

Function description

APM800

(class 0.5s)

APM801

(class 0.2s)

APM810

(class 0.5s)

APM830

(class 0.2s)

Parameters

All parameters

Four-quadrant energy

Multi-rate energy

Pulse output of energy

Active/reactive

Demand

Real-time and maximum demand of I, P, Q,S (with time)

Extreme value statistics

Extremum of I, UL-L, UL-N, P, Q, S, PF, F, THDi, THDu in this month and last month (with time)

 

 

 

 

Power quality

Unbalance of I,UL-L,UL-N

Voltage phase angle,current phase angle

Total and 2nd-63rd harmonic content of voltage and current

-

-

Voltage crest factor

-

-

Telephone waveform factor

-

-

Current K-factor

-

-

Positive sequence, negative sequence, zero sequence voltage and current

-

-

-

Fundamental voltage and current

-

-

-

Waveform

Waveform trace display

-

-

-

Fault waveform record

-

-

-

Alarm

A total of 66 kinds of alarm types, each type can record the most recent 16 alarm records, support extended records by TF card

 

 

 

 

Event

Record the most recent 128 event records, support extended records by TF card

 

 

 

 

Communication

RS485(Modbus-RTU)

I/O

2DI+2DO

Function

Function description

APM800

(class 0.5s)

APM801

(class 0.2s)

APM810

(class 0.5s)

APM830

(class 0.2s)

Optional functions

MD82

8DI+2DO

MLOG

TF card

MA84

8AI+4AO

MCM

1 RS485(Modbus-RTU),support master mode or slave mode

 

 

 

 

MCMP

1 Profibus(Profibus-DP)

MCME

1 Ethernet(Modbus-TCP,HTTP,DHCP)

        

Note:① Accuracy of 2-42nd harmonic measurement in the frequency range of 45~65Hz is 1%, accuracy of 43-63rd harmonic measurement in frequency range of 50Hz is 2%.

② “■”:standard “-”:No “□”:Optional

   

Main Parameters

             

Technical Parameter

Value

Signal

Connection

3 phase 3 wire, 3 phase 4 wire

Frequency

45~65Hz

Voltage

Rated value: AC 100V,110V,400V,690V

Overload: 1.2 times rated value(continuous); 2 times rated value(1 second)

Power consumption: < 0.5VA (per channel)

Current

Rated value: AC 1A, 5A

Overload: 1.2 times rated value(continuous); 10 times rated value(1 second)

Power consumption: < 0.5VA (per channel)

Measurement accuracy

Voltage,current and power

Class 0.5S (APM800,APM810)

Class 0.2S (APM801,APM830)

Active power

Reactive power

Class 2(APM800, APM810), Class 0.5(APM801,830)

Harmonic

1%(2~42nd),2%(43~63rd)

Switch inputs

Passive contact inputs, built-in power supply

Relay outputs

Contact type: open contact in main part, changeover contact in module Contact capacity:3A/AC 250V 3A/DC 30V

 

Pulse output of energy

 

Output mode: Optocoupler pulse with open collector Pulse constant:4000(5A),8000(1A) imp/kWh

Analog outputs

DC 0~20mA,4~20mA,0~5V,1~5V output, accuracy class 0.5%, load resistance ≤ 500Ω

Analog inputs

DC 0~20mA,4~20mA,0~5V,1~5V input, accuracy class 0.5%

Storage card

Standard capacity:4G,TF card up to 32G capacity

Communication

RS485(Modbus-RTU)

Profibus(Profibus-DP)

Ethernet(Modbus-TCP,HTTP,DHCP)

 

Auxiliary power supply

Operating range: AC/DC 85V~265V or AC/DC 115~415V(P2)

Power consumption: Power consumption of the main part ≤ 15VA

Safety

Insulation resistance

>100MΩ

Electromagnetic compatibility

IEC 61000 standard (Level 4)

Protection level

IP54(Front)

 

Technical Parameter

Value

Environment

Operating temperature: -20 °C ~ +65 °C

Storage temperature: -20°C~+70°C

Relative humidity: ≤95%(no condensation)

Altitude: ≤2500m

Share This Items :

Product Details

APM series Three phase power meters of Acrel are ultifunction power meters that are designed according to IEC standards and synchronized with international advanced technology.

   
APM series meters have full power measurement, energy statistics, analysis of power quality and network communications and other functions, are mainly used for comperehensive monitoring of the quality of power supply network.

   
Download

 

    

     

Characteristics 

 

● Measurement: 3-phase kWh, kVarh, kW, I, U, Hz, Cosφ, Current&Voltage Unbalance, 2~63rd Harmonic, Real-time&Max Demand, Zero-sequence Current, 4-quadrant Energy and etc
● Current Rating: -/5A AC; -/1A AC (According to CTs)
● Voltage Rating: 100V, 110V, 400V, 690V AC
 Frequency: 45~65Hz
● Accuracy: Up to 0.2S (Optional)
● Communication (Main Body): RS485 (MODBUS-RTU)
● Communication (Expanded): PROFIBUS-DP; Ethernet; Secondary RS485
● Extra Function: 8DI/2DO; 8AI/4AO; SOE (with standard 4GB SD Card); Multi-rate
● Display: LCD Display
● Dimension: 96*96*90mm (L*W*H)
● Installation: Panel Embedded (Cut-out --92*92mm)
● Power Supply: 85~265V AC/DC; 115~415V AC/DC
● Standard&Certificate: CE

                                                         

                         

Front View

               

                  

Dimension  Unit:mm(in) 

 
                   
  

             

   

              

Network Structure 

 
      

    

   

          

Wiring

   
     

  

        

Photo on site 

   

         

  

    

Package 

     

    

MINIMUM PACKAGE

 

MINIMUM PACKAGE

Package Dimension(1 PC)

170*150*130mm

Package Weight(1 PC)

0.372Kg

 

WHOLE BOX PACKAGE

 

Package Dimension(36 PCS)

540*530*480mm

Package Weight(36 PCS)

14.5kG

PRODUCT HS CODE

9028301400

Latest news

A brief discussion on the application and development of wireless network meters in the ubiquitous power Internet of Things

Precision distribution,multi circuits monitoring,railway transportation,leakage current

Acrel Wireless Temperature Measuring Product Application in Netherlands Substation

Substation Operation and Maintenance Cloud Platform Solution

Professional Service

Acrel Wireless Temperature Sensor Application in South Africa

Warmly Welcome Malaysian Customers to Acrel for Technical Exchanges

Application Analysis of Acrel Prepaid Energy Meter and Energy Management System

AM5-DB Low-voltage Automatic Switching Device for Backup Power Supply Application in Dongting Substation Project of Hebei Guanyi Rongxin Technology Company

Centralized Monitoring System Solution for Wind Farms

Precision distribution monitoring solution for IDC

IoT Remote Power Monitoring Solution

Acrel at the 48th MIDDLE EAST ENERGY DUBAI 2023

Acrel Power Monitoring System Application in Pepsi Asia R&D Center

Good News! Congratulations to Acrel ADL3000-E Energy Meter for Obtaining The 1st Certificate of UL61010-2-030 Standard in China!

Acrel Hospital Isolated Power Supply Application in Malaysia

Acrel Energy Meter Application In Korea Charging Pile Manufacturer

Charging Pile Energy Management System Solution

Application of Intelligent Lighting Control System in Railway Station Building

Solar PV Energy Solution

Acrel Energy Meter Application in Base Station in Indonesia

Energy Consumption Management System Solution

Excellent Quality

Advanced Technology

Welcome to Middle East Energy 2024

Application of Wireless Temperature Measurement System in Coal Mine High Voltage Electrical Equipment

Wireless Temperature Monitoring System Solution

Welcome to ENLIP EUROPE

Hydroelectric Power Plant Measurement Device Configuration Selection And Plant Power Management System

Welcome to HANNOVER MESSE 2024

Analysis and application of unattended substation operation and maintenance cloud platform

The Impact of Grid-connected Photovoltaic Power Generation on Power Quality and Solutions

Acrel DC Energy Meter Application in Base Station in Indonesia

Application and product selection of electric power monitoring system in intelligent building

R & D Strength

Application of Hall Current Sensor in Battery Cabinet Monitoring

Application of Active Filters in Biopharmaceutical Industry

en_USEnglish